35 research outputs found

    A digital microarray using interferometric detection of plasmonic nanorod labels

    Full text link
    DNA and protein microarrays are a high-throughput technology that allow the simultaneous quantification of tens of thousands of different biomolecular species. The mediocre sensitivity and dynamic range of traditional fluorescence microarrays compared to other techniques have been the technology's Achilles' Heel, and prevented their adoption for many biomedical and clinical diagnostic applications. Previous work to enhance the sensitivity of microarray readout to the single-molecule ('digital') regime have either required signal amplifying chemistry or sacrificed throughput, nixing the platform's primary advantages. Here, we report the development of a digital microarray which extends both the sensitivity and dynamic range of microarrays by about three orders of magnitude. This technique uses functionalized gold nanorods as single-molecule labels and an interferometric scanner which can rapidly enumerate individual nanorods by imaging them with a 10x objective lens. This approach does not require any chemical enhancement such as silver deposition, and scans arrays with a throughput similar to commercial fluorescence devices. By combining single-nanoparticle enumeration and ensemble measurements of spots when the particles are very dense, this system achieves a dynamic range of about one million directly from a single scan

    A digital microarray using interferometric detection of plasmonic nanorod labels

    Full text link
    DNA and protein microarrays are a high-throughput technology that allow the simultaneous quantification of tens of thousands of different biomolecular species. The mediocre sensitivity and dynamic range of traditional fluorescence microarrays compared to other techniques have been the technology's Achilles' Heel, and prevented their adoption for many biomedical and clinical diagnostic applications. Previous work to enhance the sensitivity of microarray readout to the single-molecule ('digital') regime have either required signal amplifying chemistry or sacrificed throughput, nixing the platform's primary advantages. Here, we report the development of a digital microarray which extends both the sensitivity and dynamic range of microarrays by about three orders of magnitude. This technique uses functionalized gold nanorods as single-molecule labels and an interferometric scanner which can rapidly enumerate individual nanorods by imaging them with a 10x objective lens. This approach does not require any chemical enhancement such as silver deposition, and scans arrays with a throughput similar to commercial fluorescence devices. By combining single-nanoparticle enumeration and ensemble measurements of spots when the particles are very dense, this system achieves a dynamic range of about one million directly from a single scan.First author draf

    Digital microarrays: single-molecule readout with interferometric detection of plasmonic nanorod labels

    Full text link
    DNA and protein microarrays are a high-throughput technology that allow the simultaneous quantification of tens of thousands of different biomolecular species. The mediocre sensitivity and limited dynamic range of traditional fluorescence microarrays compared to other detection techniques have been the technology’s Achilles’ heel and prevented their adoption for many biomedical and clinical diagnostic applications. Previous work to enhance the sensitivity of microarray readout to the single-molecule (“digital”) regime have either required signal amplifying chemistry or sacrificed throughput, nixing the platform’s primary advantages. Here, we report the development of a digital microarray which extends both the sensitivity and dynamic range of microarrays by about 3 orders of magnitude. This technique uses functionalized gold nanorods as single-molecule labels and an interferometric scanner which can rapidly enumerate individual nanorods by imaging them with a 10× objective lens. This approach does not require any chemical signal enhancement such as silver deposition and scans arrays with a throughput similar to commercial fluorescence scanners. By combining single-nanoparticle enumeration and ensemble measurements of spots when the particles are very dense, this system achieves a dynamic range of about 6 orders of magnitude directly from a single scan. As a proof-of-concept digital protein microarray assay, we demonstrated detection of hepatitis B virus surface antigen in buffer with a limit of detection of 3.2 pg/mL. More broadly, the technique’s simplicity and high-throughput nature make digital microarrays a flexible platform technology with a wide range of potential applications in biomedical research and clinical diagnostics.The authors wish to thank Oguzhan Avci and Jacob Trueb for thoughtful comments and suggestions regarding numerical optimization of the optical system. This work was funded in part by a research contract with ASELSAN, Inc. and the Wallace H. Coulter Foundation 2010 Coulter Translational Award. (ASELSAN, Inc.; Wallace H. Coulter Foundation Coulter Translational Award)Accepted manuscrip

    Interferometric detection and enumeration of viral particles using Si-based microfluidics

    Full text link
    Single-particle interferometric reflectance imaging sensor enables optical visualization and characterization of individual nanoparticles without any labels. Using this technique, we have shown end-point and real-time detection of viral particles using laminate-based active and passive cartridge configurations. Here, we present a new concept for low-cost microfluidic integration of the sensor chips into compact cartridges through utilization of readily available silicon fabrication technologies. This new cartridge configuration will allow simultaneous detection of individual virus binding events on a 9-spot microarray, and provide the needed simplicity and robustness for routine real-time operation for discrete detection of viral particles in a multiplex format.This work was supported in part by a research contract with the ASELSAN Research Center, Ankara, Turkey, and in part by the European Union's Horizon 2020 FET Open program under Grant 766466-INDEX. (ASELSAN Research Center, Ankara, Turkey; 766466-INDEX - European Union's Horizon 2020 FET Open program)First author draf

    Targeted Destruction of Triple Negative Breast Cancer using Nanoparticles

    Get PDF
    Photodynamic therapy (PDT) is a combination of light and photosensitizing drug in which a photosensitizer is injected intravenously and accumulates in the tissue. This tissue is then irradiated by light at an appropriate wavelength and the drug leads to cytotoxicity with a cascade of biochemical responses which affects and inactivates the cancer cells in the tumor tissue. In the cells, PDT generally induces mitochondrial damage and apoptosis which destroy the tissue and induce an antitumor activity upon illumination. Benzoporphyrin-derivative verteporfin (BPD) and curcumin are two photosensitizer drugs having the capability in use of PDT. The therapeutic potential of BPD and curcumin as photosensitizers is limited by their low aqueous solubility and applicability. In this study, it is aimed to increase the bioavailability of these drugs to induce antitumor activity in the tumor cells. Liposomes and PLGA-based polymeric nanoparticles (PLGA NPs) are used as the drug carrier nanoparticles which have been considered as perfect carriers for cancer therapeutics and they are remarkably used in cancer therapy. BPD and curcumin-loaded liposomes and PLGA NPs were synthesized and characterized in terms of size, zeta potential, drug encapsulation efficiency and morphology. These nanoparticles were targeted towards breast cancer cell line (MDA-MB-231) in vitro MTS cytotoxicity assays and imaging

    Highly sensitive and label-free digital detection of whole cell E. coli with interferometric reflectance imaging

    Full text link
    Bacterial infectious diseases are a major threat to human health. Timely and sensitive pathogenic bacteria detection is crucial in identifying the bacterial contaminations and preventing the spread of infectious diseases. Due to limitations of conventional bacteria detection techniques there have been concerted research efforts towards development of new biosensors. Biosensors offering label free, whole bacteria detection are highly desirable over those relying on label based or pathogenic molecular components detection. The major advantage is eliminating the additional time and cost required for labeling or extracting the desired bacterial components. Here, we demonstrate rapid, sensitive and label free E. coli detection utilizing interferometric reflectance imaging enhancement allowing for visualizing individual pathogens captured on the surface. Enabled by our ability to count individual bacteria on a large sensor surface, we demonstrate a limit of detection of 2.2 CFU/ml from a buffer solution with no sample preparation. To the best of our knowledge, this high level of sensitivity for whole E. coli detection is unprecedented in label free biosensing. The specificity of our biosensor is validated by comparing the response to target bacteria E. coli and non target bacteria S. aureus, K. pneumonia and P. aeruginosa. The biosensor performance in tap water also proves that its detection capability is unaffected by the sample complexity. Furthermore, our sensor platform provides high optical magnification imaging and thus validation of recorded detection events as the target bacteria based on morphological characterization. Therefore, our sensitive and label free detection method offers new perspectives for direct bacterial detection in real matrices and clinical samples.First author draf

    Instrument-free protein microarray fabrication for accurate affinity measurements

    Get PDF
    Protein microarrays have gained popularity as an attractive tool for various fields, including drug and biomarker development, and diagnostics. Thus, multiplexed binding affinity measurements in microarray format has become crucial. The preparation of microarray-based protein assays relies on precise dispensing of probe solutions to achieve efficient immobilization onto an active surface. The prohibitively high cost of equipment and the need for trained personnel to operate high complexity robotic spotters for microarray fabrication are significant detriments for researchers, especially for small laboratories with limited resources. Here, we present a low-cost, instrument-free dispensing technique by which users who are familiar with micropipetting can manually create multiplexed protein assays that show improved capture efficiency and noise level in comparison to that of the robotically spotted assays. In this study, we compare the efficiency of manually and robotically dispensed α-lactalbumin probe spots by analyzing the binding kinetics obtained from the interaction with anti-α-lactalbumin antibodies, using the interferometric reflectance imaging sensor platform. We show that the protein arrays prepared by micropipette manual spotting meet and exceed the performance of those prepared by state-of-the-art robotic spotters. These instrument-free protein assays have a higher binding signal (~4-fold improvement) and a ~3-fold better signal-to-noise ratio (SNR) in binding curves, when compared to the data acquired by averaging 75 robotic spots corresponding to the same effective sensor surface area. We demonstrate the potential of determining antigen-antibody binding coefficients in a 24-multiplexed chip format with less than 5% measurement error.Boston University Ignition Program - Boston University; NSF -CORPS Award No. 2027109 and NSF-TT PFI Award No. 1941195 - National Science FoundationPublished versio

    Surface chemistry and morphology in single particle optical imaging

    Get PDF
    Biological nanoparticles such as viruses and exosomes are important biomarkers for a range of medical conditions, from infectious diseases to cancer. Biological sensors that detect whole viruses and exosomes with high specificity, yet without additional labeling, are promising because they reduce the complexity of sample preparation and may improve measurement quality by retaining information about nanoscale physical structure of the bio-nanoparticle (BNP). Towards this end, a variety of BNP biosensor technologies have been developed, several of which are capable of enumerating the precise number of detected viruses or exosomes and analyzing physical properties of each individual particle. Optical imaging techniques are promising candidates among broad range of label-free nanoparticle detectors. These imaging BNP sensors detect the binding of single nanoparticles on a flat surface functionalized with a specific capture molecule or an array of multiplexed capture probes. The functionalization step confers all molecular specificity for the sensor’s target but can introduce an unforeseen problem; a rough and inhomogeneous surface coating can be a source of noise, as these sensors detect small local changes in optical refractive index. In this paper, we review several optical technologies for label-free BNP detectors with a focus on imaging systems. We compare the surface-imaging methods including dark-field, surface plasmon resonance imaging and interference reflectance imaging. We discuss the importance of ensuring consistently uniform and smooth surface coatings of capture molecules for these types of biosensors and finally summarize several methods that have been developed towards addressing this challenge.Accepted manuscrip

    Highly multiplexed label-free imaging sensor for accurate quantification of small-molecule binding kinetics

    Full text link
    Investigating the binding interaction of small molecules to large ligands is a compelling task for the field of drug development, as well as agro-biotechnology, since a common trait of drugs and toxins is often a low molecular weight (MW). Here, we improve the limit of detection of the Interferometric Reflectance Imaging Sensor (IRIS), a label-free, highly multiplexed biosensor, to perform small-molecule screening. In this work, characterization of small molecules binding to immobilized probes in a microarray format is demonstrated, with a limit of detection of 1 pg/mm2 in mass density. First, as a proof of concept to show the impact of spatial and temporal averaging on the system noise, detection of biotin (MW = 244.3 Da) binding to a streptavidin-functionalized chip is performed and the parameters are tuned to achieve maximum signal-to-noise ratio (SNR ≈ 34). The optimized system is then applied to the screening of a 20-multiplexed antibody chip against fumonisin B1 (MW = 721.8 Da), a mycotoxin found in cereal grains. The simultaneously recorded binding curves yield an SNR ≈ 8. Five out of twenty antibodies are also screened against the toxin in a lateral flow assay, obtaining consistent results. With the demonstrated noise characteristics, further sensitivity improvements are expected with the advancement of camera sensor technology.Published versio
    corecore